Difference between revisions of "Maintenace"

From The Maker Station Wiki!
Jump to: navigation, search
(HVAC Details)
 
(7 intermediate revisions by the same user not shown)
Line 16: Line 16:
 
|Trash
 
|Trash
 
|Weekly
 
|Weekly
|Currently not enough money in the budget for trash service or dumpster<br>Someone volunteers to take trash home, uses residential service
+
|Dumpster is located outside the back of Unit 1. Please do not leave any food trash inside the office. Take it directly to the dumpster
 
|-
 
|-
 
|Front Door
 
|Front Door
Line 30: Line 30:
 
|Check for Leaks<br>Clean sink & toilet<br>Replenish toilet paper & towels
 
|Check for Leaks<br>Clean sink & toilet<br>Replenish toilet paper & towels
 
|-
 
|-
|Back Door
+
|Back Doors
 
|Weekly
 
|Weekly
 
|'''Confirm no items blocking the fire exit'''<br>'''  **Confirm no items blocking the fire exit'''<br>'''Make sure the back door fire exit is not blocked'''
 
|'''Confirm no items blocking the fire exit'''<br>'''  **Confirm no items blocking the fire exit'''<br>'''Make sure the back door fire exit is not blocked'''
 
|-
 
|-
|Roll Up Door
+
|Roll Up Doors
 
|Weekly
 
|Weekly
 
|Confirm roll up chain is not binding
 
|Confirm roll up chain is not binding
 
|-
 
|-
|Back Shop
+
|Back Shops
 
|Weekly
 
|Weekly
 
|Vacuum & Sweep sawdust and debris
 
|Vacuum & Sweep sawdust and debris
 +
|Confirm dust collectors are not full
 
|}
 
|}
  
 
==HVAC Details==
 
==HVAC Details==
There are 3 HVAC zones in the space:
+
There are 2 HVAC zones in the space:
  
'''Front'''
+
'''Unit 1'''
* Thermostat Controls both Heating & Cooling to the front rooms. The unit is located above the bathroom
+
* Thermostat Controls both Heating & Cooling to the office space
* Air Filter 20x20x1, needs to be taped to the grating to keep it from moving when the system turns on, or get a custom sized filter
+
* The unit is located above the bathroom.
'''Classroom'''
 
* Thermostat Controls both Heating & Cooling to the classroom only. The unit is located above the classroom just above the door to the back shop
 
* Air Filter 20x20x1
 
 
'''Shop'''
 
'''Shop'''
* Furnace provides heat only.  Unit is mounted off of the ceiling way back above the bathroom... but only heats the back shop
+
* Unit 1 furnace provides heat only only to the wood shop.
  
 
==Electrical==
 
==Electrical==
Circuit Breaker is located next to the Vending Machine
+
Circuit Breakers are located in the utility closet, the wall of the woodshop, and the wall of the metal shop. If a circuit is tripped, the relevant breaker will show an orange indicator. '''ALWAYS POWER OFF ALL EQUIPMENT PLUGGED IN BEFORE RESETING A BREAKER.'''
 +
*Utility Closet 200A
 +
** Circuits in the office, including the laser, terminate here.
 +
*Wood Shop 100A
 +
** Most outlets in the wood shop terminate here.
 +
*Metal Shop 80A
 +
** This subpanel contains all circuits in the metal shop.
  
 
==Fire Protection==
 
==Fire Protection==
 
Fire Code compliance
 
Fire Code compliance
  
'''Fire Extinguishers:'''  There are two certified wall mounted fire extinguishers for the space:
+
'''Fire Extinguishers:'''  There are six wall mounted fire extinguishers for the space:
* Front: in lobby in front of the 3D Printer room
+
* Unit 1:
* Back Shop: by the door next to the CNC
+
** Front lobby by kitchenette
In addition there is a consumer grade fire extinguisher mounted on the all in the 3D Printer Room, and there is another on top of the fridge
+
** Woodshop by office door
 +
** Woodshop on pillar by SawStop
 +
** Woodshop by rear walk-in door
 +
** Electronics Room near Laser (C02)
 +
** 3d Printing Room by door

Latest revision as of 05:57, 16 June 2023

HanChewie-repairs.jpg


The space requires minimal maintenance but the items detailed below are required. Use the Blog:Maintenance to log maintenance activities.
Report all findings, issues, questions, and concerns to the makerspace Board of Directors


Maintenance Items
Item Frequency Notes
Trash Weekly Dumpster is located outside the back of Unit 1. Please do not leave any food trash inside the office. Take it directly to the dumpster
Front Door Weekly Confirm door/lock are in good condition.
Sweep Entrance
HVAC Twice per year There are 3 HVAC zones in the space
see details below
Bathroom Monthly Check for Leaks
Clean sink & toilet
Replenish toilet paper & towels
Back Doors Weekly Confirm no items blocking the fire exit
**Confirm no items blocking the fire exit
Make sure the back door fire exit is not blocked
Roll Up Doors Weekly Confirm roll up chain is not binding
Back Shops Weekly Vacuum & Sweep sawdust and debris Confirm dust collectors are not full

HVAC Details

There are 2 HVAC zones in the space:

Unit 1

  • Thermostat Controls both Heating & Cooling to the office space
  • The unit is located above the bathroom.

Shop

  • Unit 1 furnace provides heat only only to the wood shop.

Electrical

Circuit Breakers are located in the utility closet, the wall of the woodshop, and the wall of the metal shop. If a circuit is tripped, the relevant breaker will show an orange indicator. ALWAYS POWER OFF ALL EQUIPMENT PLUGGED IN BEFORE RESETING A BREAKER.

  • Utility Closet 200A
    • Circuits in the office, including the laser, terminate here.
  • Wood Shop 100A
    • Most outlets in the wood shop terminate here.
  • Metal Shop 80A
    • This subpanel contains all circuits in the metal shop.

Fire Protection

Fire Code compliance

Fire Extinguishers: There are six wall mounted fire extinguishers for the space:

  • Unit 1:
    • Front lobby by kitchenette
    • Woodshop by office door
    • Woodshop on pillar by SawStop
    • Woodshop by rear walk-in door
    • Electronics Room near Laser (C02)
    • 3d Printing Room by door